An intercom call to a zone group is a call transmitted from a Control Unit
and received by the Control Units under the same group (see 4.1.6.B ó
4.1.8.B Control Unit Installation: Group)
A general call is a call to group #0. All the Control Units belong to group
#0 and therefore receive the intercom call unless inercom call reception is
blocked at that time (see 4.1.3.H. Permissions for Intercom Calls
Operations).
The key switches between “individual identification” and
“group identification”. The zone identification number keyed will be
read as individual or group depending on the “gr” status on the
display.
Pressing the group key in general calls is redundant because
identification 0 only refers to group identification or general calls
(zone 0 does not exist).
4.1.3.B. General Calls And Zone Group Calls
Auto response is not possible in this type of calls.
The volume of the intercom call received is the volume programmed in
sections 4.1.4.H or 4.1.7.G Receive Intercom Calls Volume. To adjust
the volume, use the +/- keys while the intercom call is being received
(when the intercom call is over, the volume setting will be stored in
memory).
Changing the intercom call receipt volume
1
FM
2
1
4
3
2
7
65
Either of the two parties may initiate a conversation at any
time by pressing the key.
Either of the two parties may end the intercom conversation at
any time by pressing the key.
When said key is held , further to canceling the receipt of the call, the control unit will switch to “do not disturb” mode.
The maximum duration of an intercom operation (calls + responses) is 3 minutes.
Initiating a conversation
Ending an intercom call operation
It is possible to totally or partially block the call/auto-response process.
See 4.1.3.E.”Do not disturb” function and 4.1.3.H. Intercom Call
Permissions.. When a Control Unit cannot receive intercom calls, the
icon will be lit if the block is permanent or flashing if the “Do not
disturb” function is activated.